Taylor & Francis Group
Browse
1/1
2 files

Fine particle mass monitoring with low-cost sensors: Corrections and long-term performance evaluation

Version 3 2020-01-13, 21:19
Version 2 2019-06-10, 16:19
Version 1 2019-05-30, 16:23
dataset
posted on 2020-01-13, 21:19 authored by Carl Malings, Rebecca Tanzer, Aliaksei Hauryliuk, Provat K. Saha, Allen L. Robinson, Albert A. Presto, R Subramanian

Low-cost sensors for the measurement of fine particulate matter mass (PM2.5) enable dense networks to increase the spatial resolution of air quality monitoring. However, these sensors are affected by environmental factors such as temperature and humidity and their effects on ambient aerosol, which must be accounted for to improve the in-field accuracy of these sensors. We conducted long-term tests of two low-cost PM2.5 sensors: Met-One NPM and PurpleAir PA-II units. We found a high level of self-consistency within each sensor type after testing 25 NPM and 9 PurpleAir units. We developed two types of corrections for the low-cost sensor measurements to better match regulatory-grade data. The first correction accounts for aerosol hygroscopic growth using particle composition and corrects for particle mass below the optical sensor size cut-point by collocation with reference Beta Attenuation Monitors (BAM). A second, fully-empirical correction uses linear or quadratic functions of environmental variables based on the same collocation dataset. The two models yielded comparable improvements over raw measurements. Sensor performance was assessed for two use cases: improving community awareness of air quality with short-term semi-quantitative comparisons of sites and providing long-term reasonably quantitative information for health impact studies. For the short-term case, both sensors provided reasonably accurate concentration information (mean absolute error of ∼4 µg/m3) in near-real time. For the long-term case, tested using year-long collocations at one urban background and one near-source site, error in the annual average was reduced below 1 µg/m3. Hence, these sensors can supplement sparse networks of regulatory-grade instruments, perform high-density neighborhood-scale monitoring, and be used to better understand spatial patterns and temporal air quality trends across urban areas.

Copyright © 2019 American Association for Aerosol Research

Funding

This publication was developed under Assistance Agreement No. 836286 and as part of the Center for Air, Climate, and Energy Solutions (CACES), which was supported under Assistance Agreement No. 835873, both awarded by the U.S. Environmental Protection Agency to Carnegie Mellon University. It has not been formally reviewed by EPA. The views expressed in this document are solely those of the authors and do not necessarily reflect those of the Agency. EPA does not endorse any products or commercial services mentioned in this publication. This work is also supported by the Heinz Endowment Fund (Grants E2375 and E3145).

History