Taylor & Francis Group
Browse
iblo_a_1645586_sm0770.doc (34 kB)

The intensity of oscillations of the photoplethysmographic waveform variability at frequencies 0.04–0.4 Hz is effective marker of hypertension and coronary artery disease in males

Download (34 kB)
journal contribution
posted on 2019-08-12, 12:02 authored by Anton R. Kiselev, Anatoly S. Karavaev

Background: It is believed that the intensity of oscillations in the photoplethysmographic waveform variability reflects the activity of vascular regulatory mechanisms. However, the relationship of such fluctuations with the state of health is poorly understood.

Purpose: The aim of our study was to assess the possibility of using spectral indices that reflect the intensity of oscillations of the photoplethysmographic waveform variability at frequencies 0.04-0.4 Hz as markers of hypertension and coronary artery disease. We did not study women to exclude the influence of menopause and sex hormones on the results.

Materials and Methods: We compared synchronous 10-minute records of finger photoplethysmogram and respiration at rest in 30 healthy males (48.8 ± 4.5 years; data presented as Mean ± SD) versus 30 patients with hypertension (aged 49.0 ± 4.3 years) versus 30 patients with stable coronary artery disease (49.2 ± 4.8 years). Percentages of high-frequency and low-frequency ranges in the total power of photoplethysmographic waveform variability spectrum (HF% and LF%), and LF/HF ratio were assessed.

Results: HF% are subject to by 2- to 5-fold increase in hypertensive patients (p < .001) and up to an 8-fold increase in patients with coronary artery disease (p < .001) when compared with healthy persons. On the contrary, LF% is reduced by 1.5-5 times in all patients when compared with healthy people (p < .001). We identified cut-off points for each photoplethysmographic index to distinguish patients with coronary artery disease or hypertension from healthy subjects. Multiple logistic regression models based on photoplethysmographic waveform variability indices had sufficient sensitivity and specificity for patients with hypertension or coronary artery disease.

Conclusion: Frequency-domain indices of photoplethysmographic waveform variability (in particular, HF%, LF%, and LF/HF) are sufficiently sensitive and specific markers of hypertension and coronary artery disease in adult males.

History

Usage metrics

    Blood Pressure

    Licence

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC